The TM 286 Auto Tymp is a versatile combination instrument that provides testing capability for tympanometry alone, tympanometry combined with screening acoustic reflex measurements, and screening audiometry. An optional soft-sided carrying case is available for portability. Also, a patient handswitch, patch cords, and earphone sound enclosures may be purchased as optional accessories.
The TM 286 is an upgrade from the TM282 model.
The Welch Allyn TM 286 AutoTymp ® provides flexible screening for tympanometry, acoustic reflex measurements and audiometry to meet your testing needs today and in the future. The TM 286 AutoTymp is lightweight and portable. It is designed to make detection and documentation of middle ear pathologies fast and accurate.
Features
Tympanometry: 226 H
•Ear Canal Volume (ECV)
•Compliance Peak (cm3)
•Pressure at peak of the tymp (daPa)
•Gradient (GR) in daPa (width of the tymp)
The tympanograms and the following summary information are clearly shown on the crisp LCD once the test is complete. LEDs on the probe guide the tester through the test sequence. All test results can be print on the internal printer. The ASHA normal box can be shown as a guide on he display and printouts, if desired. A hand-held probe is provided withversions providing 226 Hz only measurements.
Both manual and automated audiometry are available with the TM 286. During manual audiometry, the operator controls the selection of frequencies, signal format (steady, pulsed and FM), intensity, tone presentation and identification of the hearing threshold values per frequency tested. For automated audiometry, the test protocol is selected in the Program modeand includes frequencies to be tested, signal format, intensity range and scoring rules. Once the test begins, the test sequence is controlled by the TM 286 based upon the operation of the optional hand switch by the person being tested. Test results are displayed as an audiogram on the LCD as they become available. These results can be printed in a tabular or audiogram format. The standard headset for audiometry is the TDH 39. However, the EAR 3A or 5A insert phones may be added as an option. It is possible to store the calibration values for both the TDH and insert phones so that a button press selects the transducer and its calibration.
Pure Tone & Tympanometry Screener Setting the Clinical Standard
Tymp and Reflex
Ipsilateral reflex measurements may be performed along with 226 Hz tympanometry. The frequencies available are 500, 1000, 2000 and 4000 Hz. All reflex results may be displayed and printed as:
•Reflex tracings and dB HL values
•dB HL values only
•Yes/No response
Any combination of ipsi reflex measurements up to a maximum of four frequencies may be selected.
26241 TM Test Cavity
28206 Threshold Audiometry Card
28209 Audiometry Headset External
28600 TM 286 Prode Assembly
28601 TM 286 Power Brick (113-4050800)