506N3 VitalCare Series Criticare Patient Monitor

  • Criticare VitalCare 506 Series Vital Signs Monitor
  • Image 2


Call For The Low Price:

The manufacturer will not let us publish our surprisingly low prices

Ask A Question About This Product
SKU:
506N3
Brand:
hide




VitalCare Series Patient Monitors
MULTIPLE CONFIGURATIONS/ BATTERY MANAGEMENT/ COST EFFECTIVE

Recomended For Dental Offices, Oral Surgery, Medical and Surgical

Proprietary ComfortCuff NIPB, Pulse Oximetery, and predictive temperatures in one compact, easily transported monitor. Ideal for Spot Checks or continous vital signs monitoring.

Features

  • DOX or Nellcor OxiMax SpO2 technology
  • Proprietary ComfortCuff NIBP measures on inflation for faster, more comfortable readings
  • Optional FILAC FasTemp predictive temperature with predictive and monitoring modes delivers quick, accurate measurements
  • Audible and visual alarms provide instant notification
  • Lightweight design and versatile mounting options—adapts readily to department and transport requirements
  • Optional internal printer for demand, automatic interval, or trend reports.
    Smart battery management with rechargeable sealed lead acid battery

Non-Invasive Blood Pressure

  • Technique: Oscillometric measure upon inflation
  • Measurement Time: <40 seconds typical; 0 to 300mmHg;
    standard adult cuff
  • Automatic Measurement
  • Cycles: 1 - 60 minute; 2 - 4 hour; STAT
  • Inflation Pressure Range: 30 to 300mmHg (Adult)
    30 to 150mmHg (Pediatric)
    20 to 150mmHg (Neonate)
  • Resolution: 1mmHg
  • Clinical Accuracy: SP-10:2002
  • Transducer Accuracy: ±2mmHg or ±2% of reading, whichever is
    greater, over full range
  • STAT mode: 5 minutes of consecutive readings

Pulse Oximetry

  • Range: 1% to 99%
  • Resolution: 1%
  • Accuracy (DOX only): 70% to 99% range: ±2%;
    50% to 69% range: ±3%;
    <50%: unspecified
  • Accuracy (OxiMax Only): 70% to 99% range: ±2%;
    <70%: unspecified
  • Method: Dual wavelength LED
  • Audio: Tone with each detected pulse; pitch varies
    with saturation
  • Heart (Pulse) Rate
  • Range: 20 to 300bpm
  • Accuracy (DOX only): Greater of ±1bpm or ±1%, of reading
    Unspecified for 240 bpm
  • Accuracy (OxiMax only): Greater of ±1bpm or ±1%, of reading
    Unspecified for 240 bpm
  • Update Time: Every second
  • Resolution: 1bpm
  • Pulse Volume: 10 levels or Off

Temperature (optional)

  • Type: FILAC FasTemp
  • Method: Predictive or Continuous
  • Channels: 1
  • Range: 30.0º to 43.0º C
  • Accuracy: ±0.2º C for 30.0º to 36.9ºC;
    ±0.1º C for 37.0º to 39.0ºC;
    ±0.2º C for 39.1º to 43.0ºC
  • Resolution: 0.1º F or 0.1º C
  • Predictive Response Time: Oral: less than 10 seconds;
    Axial: less than 10 seconds
  • Rectal: less than 10 seconds
  • Probes/Wells: Oral/Axial FILAC FasTemp [202026]
    Rectal FILAC FasTemp (optional) [202034]
    Isolation Well, Oral/Axial [202089]
    Isolation Well, Rectal (optional) [202087]

Alarms

  • Indication: Audible; Visual
  • Volume: 10 levels or Off
  • Silence: Yes; 2 minutes or permanent

Trend Memory

  • Memory: Last 24 hours
  • Parameters: SpO2, pulse rate, NIBP, temperature
  • Report Types: Single Patient or Multi-patient; Selectable formats

Monitor Configurations:

506N3 - NIBP, Heart Rate

506NP3 - NIBP, Heart Rate, Printer

506NT3 - NIBP, Heart Rate, FILAC FasTemp™ Temperature

506NTP3 - NIBP, Heart Rate, FILAC FasTemp™ Temperature, Printer

506DN3 - DOX™ SpO2, NIBP, Heart Rate

506DNP3 - DOX™ SpO2, NIBP, Heart Rate, Printer

506DNT3 - DOX™ SpO2, NIBP, Heart Rate, Temperature

506DNTP3 - DOX™ SpO2, NIBP, Heart Rate, Temperature, Printer

506LN3 - OxiMax™ SpO2, NIBP, Heart Rate

506LNP3 - OxiMax™ SpO2, NIBP, Heart Rate, Printer

506LNT3 - OxiMax™ SpO2, NIBP, Heart Rate, Temperature

506LNTP3 - OxiMax™ SpO2, NIBP, Heart Rate, Temperature, Printer

506NV3 - NIBP, Heart Rate, TurboTemp™ Temperature

506NVP3 - NIBP, Heart Rate, TurboTemp™ Temperature, Printer

506DNV3 - DOX™ SpO2, NIBP, Heart Rate, TurboTemp™ Temperature

506DNVP3 - DOX™ SpO2, NIBP, Heart Rate, TurboTemp™ Temperature, Printer

506LNV3 - OxiMax™ SpO2, NIBP, Heart Rate, TurboTemp™ Temperature

506LNVP3 - OxiMax™ SpO2, NIBP, Heart Rate, TurboTemp™ Temperature, Printer

What's In The Box?
  • Adult BP Cuff
  • Large Adult BP Cuff
  • NIBP Hose
  • Power Cord (North American)
  • Operators Manual
  • Help Card
  • Probe Covers (Box of 20) *Temp Units Only
  • FasTemp Oral Temp Probe *Temp Units Only
  • Isolation Well for Oral Probe *Temp Units Only

Download 506N3 Documentation PDF

 

 


Warranty Information

2 full years